Filter Pack 500
Anti-pollution device,
post treatment
assembly example
of the filterpac 500
on the blast chiller
Filterpack 500 is a post-water treatment anti-pollution device.
It can be used on micro particulate abatement systems. Very effective for achieving optimal results with a maximum air flow rate of up to 500 m³ / h
AFTER-TREATMENT AND REFINING EQUIPMENT
In case you want to eliminate odors more, or want to reduce the diffusion of steam coming out of the machine, or
even in the case of fumes for which additional treatments are required, a post-treatment apparatus is available which is based on various types of filtering septa, applicable at the machine outlet.
Due to its resistance, this device must necessarily be equipped with a fan and inverter.
The Filterpack is a filter holder with 4 grooves for the support of the filters themselves. Can't lean directly
on the machine, as the outlet of the machine itself and the dimensions of the filterpack are not the same.
There is therefore a collector, which must be linked to the machine outlet with an array of screws. A second crown of screws will bind the manifold to the box. The joints must be siliconed.
A hopper (supplied) must be installed above the box, which is also fixed by screws and silicone.
Above all, the fan must be fixed, by means of its joint d. 250 male / female.
It is advisable to fix the fan to a fixed support (eg with wall brackets of suitable length) so that it does not vibrate.
NOTE:
The FILTERPACK device does not guarantee absolute filtration. In some cases, between the blast chiller and the filterpack, it comes
made an opening, equipped with a butterfly valve, in order to let in fresh air, which contributes to the condensation of the vapor.